HT-250SP Ziant

  • HT-250SP II Ziant : Cooling and heating on engine operation
  • HT-250SPES II Ziant : Cooling and heating on engine and electric operation
  • 3TNV-70HT, Clean and silent engine
  • 3cylinders, liquid-cooled
  • 854cc displacement
  • 6 liter oil capacity
  • Bock FKX30-235TK (made in Germany)
  • 2 cylinders, 233cc displacement
  • 2 liter oil charge
TEMP. ENGINE POWER ELECTRIC POWER
0℃ 5,800 watts 4,367 watts
-20℃ 3,225 watts 2,450 watts

Refrigeration cooling capacity at 30℃ ambient under ATP standards

  • Automatic stop/start control system
  • Automatic defrost initiation and termination by microprocessor
  • Automatic defrost initiation with air switch
  • Continuous system monitoring
  • Programmable set point range
  • Easy distinction of double temp. system
  • ABS Plastic front cover and side doors
  • Aluminum evaporator case
  • Stainless muffler, surge tank, evaporator guard
  • 2700rpm DC motor, three evaporator fans 250mm diameter
  • Airflow 2,561m³/h
  • 5HP, high performance AC motor
  • 220V/380V/415V, 3Phase, 50/60Hz
  • Engine low oil pressure cutout
  • Engine coolant high temperature cutout
  • Refrigerant high/low pressure cutout
  • Motor overload relay{HT-250SPES II Ziant only}
  • Ozone protection, non CFC R-404a
  • Chlorine free, Charge : 2.8kg

Aluminum guard protect the system

  • Installation hardware
  • Fuel pumps, Fuel lines
  • Fuel filter, Air Cleaner, Oil filter
  • Battery case, cables
  • HT-250SP II Ziant : 355kg
  • HT-250SPES II Ziant : 380kg
  • Dual temperature system for two compartments
  • Heating system: when the ambient is lower than the temperature in the truck body then, heating system{hot gas, hot water & electric coil} is used to protect the products from frozen.
  • Temperature recorder : System monitoring system, Single or two channel
  • External on/off switch
  • External engine / electric hour meter
  • Rear view camera and sensor